Files
percona-toolkit/t/pt-summary/parse_lsi_megaraid.sh
Daniel Nichter 4d462bbbdd Fix Bash tests.
2012-02-02 10:03:48 -07:00

697 lines
20 KiB
Bash

#!/bin/bash
TESTS=6
TMPDIR=$TEST_TMPDIR
# ############################################################################
cat <<EOF > $TMPDIR/expected
BBU | 100% Charged, Temperature 18C, isSOHGood=Yes
EOF
cat <<EOF > $TMPDIR/in
BBU status for Adapter: 0
BatteryType: BBU
Voltage: 4072 mV
Current: 0 mA
Temperature: 18 C
Firmware Status: 00000000
Battery state:
GasGuageStatus:
Fully Discharged : No
Fully Charged : Yes
Discharging : Yes
Initialized : Yes
Remaining Time Alarm : No
Remaining Capacity Alarm: No
Discharge Terminated : No
Over Temperature : No
Charging Terminated : No
Over Charged : No
Relative State of Charge: 100 %
Charger Status: Complete
Remaining Capacity: 867 mAh
Full Charge Capacity: 867 mAh
isSOHGood: Yes
Exit Code: 0x00
EOF
parse_lsi_megaraid_bbu_status $TMPDIR/in > $TMPDIR/got
no_diff $TMPDIR/got $TMPDIR/expected
# ############################################################################
cat <<EOF > $TMPDIR/expected
PhysiclDev Type State Errors Vendor Model Size
========== ==== ======= ====== ======= ============ ===========
Hard Disk SAS Online 0/0/0 SEAGATE ST373455SS 70007MB
Hard Disk SAS Online 0/0/0 SEAGATE ST373455SS 70007MB
Hard Disk SAS Online 0/0/0 SEAGATE ST373455SS 70007MB
Hard Disk SAS Online 0/0/0 SEAGATE ST373455SS 70007MB
EOF
cat <<EOF > $TMPDIR/in
Adapter #0
Enclosure Device ID: 32
Slot Number: 0
Device Id: 0
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 70007MB [0x88bb93a Sectors]
Non Coerced Size: 69495MB [0x87bb93a Sectors]
Coerced Size: 69376MB [0x8780000 Sectors]
Firmware state: Online
SAS Address(0): 0x5000c500079f8cf9
SAS Address(1): 0x0
Connected Port Number: 0(path0)
Inquiry Data: SEAGATE ST373455SS S5273LQ2DZ33
Foreign State: None
Media Type: Hard Disk Device
Enclosure Device ID: 32
Slot Number: 1
Device Id: 1
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 70007MB [0x88bb93a Sectors]
Non Coerced Size: 69495MB [0x87bb93a Sectors]
Coerced Size: 69376MB [0x8780000 Sectors]
Firmware state: Online
SAS Address(0): 0x5000c500079f5c35
SAS Address(1): 0x0
Connected Port Number: 1(path0)
Inquiry Data: SEAGATE ST373455SS S5273LQ2D9RH
Foreign State: None
Media Type: Hard Disk Device
Enclosure Device ID: 32
Slot Number: 2
Device Id: 2
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 70007MB [0x88bb93a Sectors]
Non Coerced Size: 69495MB [0x87bb93a Sectors]
Coerced Size: 69376MB [0x8780000 Sectors]
Firmware state: Online
SAS Address(0): 0x5000c500079fc0c9
SAS Address(1): 0x0
Connected Port Number: 2(path0)
Inquiry Data: SEAGATE ST373455SS S5273LQ2DPST
Foreign State: None
Media Type: Hard Disk Device
Enclosure Device ID: 32
Slot Number: 3
Device Id: 3
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 70007MB [0x88bb93a Sectors]
Non Coerced Size: 69495MB [0x87bb93a Sectors]
Coerced Size: 69376MB [0x8780000 Sectors]
Firmware state: Online
SAS Address(0): 0x5000c500079dc339
SAS Address(1): 0x0
Connected Port Number: 3(path0)
Inquiry Data: SEAGATE ST373455SS S5273LQ2CKD5
Foreign State: None
Media Type: Hard Disk Device
Exit Code: 0x00
EOF
parse_lsi_megaraid_devices $TMPDIR/in > $TMPDIR/got
no_diff $TMPDIR/got $TMPDIR/expected
# ############################################################################
cat <<EOF > $TMPDIR/expected
PhysiclDev Type State Errors Vendor Model Size
========== ==== ======= ====== ======= ============ ===========
Hard Disk SAS Online 0/0/0 SEAGATE ST373455SS 70007MB
Hard Disk SAS Online 0/0/0 SEAGATE ST373455SS 70007MB
Hard Disk SAS Online 0/0/0 SEAGATE ST373455SS 70007MB
Hard Disk SAS Online 0/0/0 SEAGATE ST373455SS 70007MB
EOF
cat <<EOF > $TMPDIR/in
[root@pc-db1 ~]# /opt/MegaRAID/MegaCli/MegaCli64 -LdPdInfo -aALL
Adapter #0
Number of Virtual Disks: 2
Virtual Disk: 0 (Target Id: 0)
Name:
RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0
Size:69376MB
State: Optimal
Stripe Size: 64kB
Number Of Drives:2
Span Depth:1
Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Access Policy: Read/Write
Disk Cache Policy: Disk's Default
Number of Spans: 1
Span: 0 - Number of PDs: 2
PD: 0 Information
Enclosure Device ID: 32
Slot Number: 0
Device Id: 0
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 70007MB [0x88bb93a Sectors]
Non Coerced Size: 69495MB [0x87bb93a Sectors]
Coerced Size: 69376MB [0x8780000 Sectors]
Firmware state: Online
SAS Address(0): 0x5000c500079f8cf9
SAS Address(1): 0x0
Connected Port Number: 0(path0)
Inquiry Data: SEAGATE ST373455SS S5273LQ2DZ33
Foreign State: None
Media Type: Hard Disk Device
PD: 1 Information
Enclosure Device ID: 32
Slot Number: 1
Device Id: 1
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 70007MB [0x88bb93a Sectors]
Non Coerced Size: 69495MB [0x87bb93a Sectors]
Coerced Size: 69376MB [0x8780000 Sectors]
Firmware state: Online
SAS Address(0): 0x5000c500079f5c35
SAS Address(1): 0x0
Connected Port Number: 1(path0)
Inquiry Data: SEAGATE ST373455SS S5273LQ2D9RH
Foreign State: None
Media Type: Hard Disk Device
Virtual Disk: 1 (Target Id: 1)
Name:
RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0
Size:69376MB
State: Optimal
Stripe Size: 64kB
Number Of Drives:2
Span Depth:1
Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Access Policy: Read/Write
Disk Cache Policy: Disk's Default
Number of Spans: 1
Span: 0 - Number of PDs: 2
PD: 0 Information
Enclosure Device ID: 32
Slot Number: 2
Device Id: 2
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 70007MB [0x88bb93a Sectors]
Non Coerced Size: 69495MB [0x87bb93a Sectors]
Coerced Size: 69376MB [0x8780000 Sectors]
Firmware state: Online
SAS Address(0): 0x5000c500079fc0c9
SAS Address(1): 0x0
Connected Port Number: 2(path0)
Inquiry Data: SEAGATE ST373455SS S5273LQ2DPST
Foreign State: None
Media Type: Hard Disk Device
PD: 1 Information
Enclosure Device ID: 32
Slot Number: 3
Device Id: 3
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 70007MB [0x88bb93a Sectors]
Non Coerced Size: 69495MB [0x87bb93a Sectors]
Coerced Size: 69376MB [0x8780000 Sectors]
Firmware state: Online
SAS Address(0): 0x5000c500079dc339
SAS Address(1): 0x0
Connected Port Number: 3(path0)
Inquiry Data: SEAGATE ST373455SS S5273LQ2CKD5
Foreign State: None
Media Type: Hard Disk Device
Exit Code: 0x00
EOF
parse_lsi_megaraid_devices $TMPDIR/in > $TMPDIR/got
no_diff $TMPDIR/got $TMPDIR/expected
# ############################################################################
cat <<EOF > $TMPDIR/expected
VirtualDev Size RAID Level Disks SpnDpth Stripe Status Cache
========== ========= ========== ===== ======= ====== ======= =========
0(no name) 69376MB 1 (1-0-0) 2 1-1 64kB Optimal WB, no RA
1(no name) 69376MB 1 (1-0-0) 2 1-1 64kB Optimal WB, no RA
EOF
cat <<EOF > $TMPDIR/in
[root@pc-db1 ~]# /opt/MegaRAID/MegaCli/MegaCli64 -LdPdInfo -aALL
Adapter #0
Number of Virtual Disks: 2
Virtual Disk: 0 (Target Id: 0)
Name:
RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0
Size:69376MB
State: Optimal
Stripe Size: 64kB
Number Of Drives:2
Span Depth:1
Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Access Policy: Read/Write
Disk Cache Policy: Disk's Default
Number of Spans: 1
Span: 0 - Number of PDs: 2
PD: 0 Information
Enclosure Device ID: 32
Slot Number: 0
Device Id: 0
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 70007MB [0x88bb93a Sectors]
Non Coerced Size: 69495MB [0x87bb93a Sectors]
Coerced Size: 69376MB [0x8780000 Sectors]
Firmware state: Online
SAS Address(0): 0x5000c500079f8cf9
SAS Address(1): 0x0
Connected Port Number: 0(path0)
Inquiry Data: SEAGATE ST373455SS S5273LQ2DZ33
Foreign State: None
Media Type: Hard Disk Device
PD: 1 Information
Enclosure Device ID: 32
Slot Number: 1
Device Id: 1
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 70007MB [0x88bb93a Sectors]
Non Coerced Size: 69495MB [0x87bb93a Sectors]
Coerced Size: 69376MB [0x8780000 Sectors]
Firmware state: Online
SAS Address(0): 0x5000c500079f5c35
SAS Address(1): 0x0
Connected Port Number: 1(path0)
Inquiry Data: SEAGATE ST373455SS S5273LQ2D9RH
Foreign State: None
Media Type: Hard Disk Device
Virtual Disk: 1 (Target Id: 1)
Name:
RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0
Size:69376MB
State: Optimal
Stripe Size: 64kB
Number Of Drives:2
Span Depth:1
Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Access Policy: Read/Write
Disk Cache Policy: Disk's Default
Number of Spans: 1
Span: 0 - Number of PDs: 2
PD: 0 Information
Enclosure Device ID: 32
Slot Number: 2
Device Id: 2
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 70007MB [0x88bb93a Sectors]
Non Coerced Size: 69495MB [0x87bb93a Sectors]
Coerced Size: 69376MB [0x8780000 Sectors]
Firmware state: Online
SAS Address(0): 0x5000c500079fc0c9
SAS Address(1): 0x0
Connected Port Number: 2(path0)
Inquiry Data: SEAGATE ST373455SS S5273LQ2DPST
Foreign State: None
Media Type: Hard Disk Device
PD: 1 Information
Enclosure Device ID: 32
Slot Number: 3
Device Id: 3
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 70007MB [0x88bb93a Sectors]
Non Coerced Size: 69495MB [0x87bb93a Sectors]
Coerced Size: 69376MB [0x8780000 Sectors]
Firmware state: Online
SAS Address(0): 0x5000c500079dc339
SAS Address(1): 0x0
Connected Port Number: 3(path0)
Inquiry Data: SEAGATE ST373455SS S5273LQ2CKD5
Foreign State: None
Media Type: Hard Disk Device
Exit Code: 0x00
EOF
parse_lsi_megaraid_virtual_devices $TMPDIR/in > $TMPDIR/got
no_diff $TMPDIR/got $TMPDIR/expected
# ############################################################################
cat <<EOF > $TMPDIR/expected
VirtualDev Size RAID Level Disks SpnDpth Stripe Status Cache
========== ========= ========== ===== ======= ====== ======= =========
0(no name) 69376MB 1 (1-0-0) 2 1- 64kB Optimal WB, no RA
1(no name) 69376MB 1 (1-0-0) 2 1- 64kB Optimal WB, no RA
EOF
cat <<EOF > $TMPDIR/in
[root@pc-db1 ~]# /opt/MegaRAID/MegaCli/MegaCli64 -LDInfo -Lall -aAll
Adapter 0 -- Virtual Drive Information:
Virtual Disk: 0 (Target Id: 0)
Name:
RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0
Size:69376MB
State: Optimal
Stripe Size: 64kB
Number Of Drives:2
Span Depth:1
Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Access Policy: Read/Write
Disk Cache Policy: Disk's Default
Virtual Disk: 1 (Target Id: 1)
Name:
RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0
Size:69376MB
State: Optimal
Stripe Size: 64kB
Number Of Drives:2
Span Depth:1
Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
Access Policy: Read/Write
Disk Cache Policy: Disk's Default
Exit Code: 0x00
EOF
parse_lsi_megaraid_virtual_devices $TMPDIR/in > $TMPDIR/got
no_diff $TMPDIR/got $TMPDIR/expected
# ############################################################################
cat <<EOF > $TMPDIR/expected
Model | PERC 6/i Integrated, PCIE interface, 8 ports
Cache | 256MB Memory, BBU Present
EOF
cat <<EOF > $TMPDIR/in
[root@pc-db1]# /opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALL
Adapter #0
==============================================================================
Versions
================
Product Name : PERC 6/i Integrated
Serial No : 1122334455667788
FW Package Build: 6.0.1-0080
Mfg. Data
================
Mfg. Date : 06/08/07
Rework Date : 06/08/07
Revision No :
Battery FRU : N/A
Image Versions In Flash:
================
FW Version : 1.11.52-0349
BIOS Version : NT13-2
WebBIOS Version : 1.1-32-e_11-Rel
Ctrl-R Version : 1.01-010B
Boot Block Version : 1.00.00.01-0008
Pending Images In Flash
================
None
PCI Info
================
Vendor Id : 1000
Device Id : 0060
SubVendorId : 1028
SubDeviceId : 1f0c
Host Interface : PCIE
Number of Frontend Port: 0
Device Interface : PCIE
Number of Backend Port: 8
Port : Address
0 5000c500079f8cf9
1 5000c500079f5c35
2 5000c500079fc0c9
3 5000c500079dc339
4 0000000000000000
5 0000000000000000
6 0000000000000000
7 0000000000000000
HW Configuration
================
SAS Address : 5001e4f021048f00
BBU : Present
Alarm : Absent
NVRAM : Present
Serial Debugger : Present
Memory : Present
Flash : Present
Memory Size : 256MB
Settings
================
Current Time : 20:31:29 5/13, 2010
Predictive Fail Poll Interval : 300sec
Interrupt Throttle Active Count : 16
Interrupt Throttle Completion : 50us
Rebuild Rate : 30%
PR Rate : 30%
Resynch Rate : 30%
Check Consistency Rate : 30%
Reconstruction Rate : 30%
Cache Flush Interval : 4s
Max Drives to Spinup at One Time : 2
Delay Among Spinup Groups : 12s
Physical Drive Coercion Mode : 128MB
Cluster Mode : Disabled
Alarm : Disabled
Auto Rebuild : Enabled
Battery Warning : Enabled
Ecc Bucket Size : 15
Ecc Bucket Leak Rate : 1440 Minutes
Restore HotSpare on Insertion : Disabled
Expose Enclosure Devices : Disabled
Maintain PD Fail History : Disabled
Host Request Reordering : Enabled
Auto Detect BackPlane Enabled : SGPIO/i2c SEP
Load Balance Mode : Auto
Any Offline VD Cache Preserved : No
Capabilities
================
RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID10, RAID50, RAID60
Supported Drives : SAS, SATA
Allowed Mixing:
Mix In Enclosure Allowed
Status
================
ECC Bucket Count : 0
Limitations
================
Max Arms Per VD : 32
Max Spans Per VD : 8
Max Arrays : 128
Max Number of VDs : 64
Max Parallel Commands : 1008
Max SGE Count : 80
Max Data Transfer Size : 8192 sectors
Max Strips PerIO : 42
Min Stripe Size : 8kB
Max Stripe Size : 1024kB
Device Present
================
Virtual Drives : 2
Degraded : 0
Offline : 0
Physical Devices : 5
Disks : 4
Critical Disks : 0
Failed Disks : 0
Supported Adapter Operations
================
Rebuild Rate : Yes
CC Rate : Yes
BGI Rate : Yes
Reconstruct Rate : Yes
Patrol Read Rate : Yes
Alarm Control : Yes
Cluster Support : No
BBU : Yes
Spanning : Yes
Dedicated Hot Spare : Yes
Revertible Hot Spares : No
Foreign Config Import : Yes
Self Diagnostic : Yes
Allow Mixed Redundancy on Array : No
Global Hot Spares : Yes
Deny SCSI Passthrough : No
Deny SMP Passthrough : No
Deny STP Passthrough : No
Supported VD Operations
================
Read Policy : Yes
Write Policy : Yes
IO Policy : Yes
Access Policy : Yes
Disk Cache Policy : Yes
Reconstruction : Yes
Deny Locate : No
Deny CC : No
Supported PD Operations
================
Force Online : Yes
Force Offline : Yes
Force Rebuild : Yes
Deny Force Failed : No
Deny Force Good/Bad : No
Deny Missing Replace : No
Deny Clear : No
Deny Locate : No
Disable Copyback : No
Enable Copyback on SMART : No
Enable Copyback to SSD on SMART error : No
Error Counters
================
Memory Correctable Errors : 0
Memory Uncorrectable Errors : 0
Cluster Information
================
Cluster Permitted : No
Cluster Active : No
Default Settings
================
Phy Polarity : 0
Phy PolaritySplit : 0
Background Rate : 30
Stripe Size : 64kB
Flush Time : 4 seconds
Write Policy : WB
Read Policy : None
Cache When BBU Bad : Disabled
Cached IO : No
SMART Mode : Mode 6
Alarm Disable : No
Coercion Mode : 128MB
ZCR Config : Unknown
Dirty LED Shows Drive Activity : No
BIOS Continue on Error : No
Spin Down Mode : None
Allowed Device Type : SAS/SATA Mix
Allow Mix In Enclosure : Yes
Allow HDD SAS/SATA Mix In VD : No
Allow SSD SAS/SATA Mix In VD : No
Allow HDD/SAS Mix In VD : No
Allow SATA In Cluster : No
Max Chained Enclosures : 1
Disable Ctrl-R : No
Enable Web BIOS : No
Direct PD Mapping : Yes
BIOS Enumerate VDs : Yes
Restore Hot Spare on Insertion : No
Expose Enclosure Devices : No
Maintain PD Fail History : No
Disable Puncturing : No
Zero Based Enclosure Enumeration : Yes
PreBoot CLI Enabled : No
LED Show Drive Activity : No
Cluster Disable : Yes
SAS Disable : No
Auto Detect BackPlane Enable : SGPIO/i2c SEP
Delay during POST : 0
Exit Code: 0x00
EOF
parse_lsi_megaraid_adapter_info $TMPDIR/in > $TMPDIR/got